Our C-STIM-150I stimulator packages are useful for applications requiring electric field stimulation. Each package includes a constant current stimulator(s), power supply cabinet, computer interface card, CATSTIM software, and interface cables. The output of each stimulator is accessible via a BNC connector.

Living Systems Instrumentation designs, develops, and manufactures instruments for in vitro research studies of pressurized, perfused, cannulated blood vessels. These include vessel chambers and electro-mechanical apparatus for the measurement and control of pressure, flow rate and vessel dimensions. Living Systems also offers an array of laboratory equipment that are essential to any successful research project!

Request a Quote

Dual Channel Constant Current Stim Pkg

Quad Channel Constant Current Stim Pkg

Single Channel Constant Current Stim Pkg

Stimulator Package for Constant Current Electrical Field Stimulation – 8 Channel

SOF-152_CATSTIM-Software_TwoChamber_web_04v1-1.jpg SOF-152_CATSTIM-Software_FourChamber_web_03v1-2.jpg SOF-152_CATSTIM-Software_OneChamber_web_01v1.jpg SOF-152_CATSTIM-Software_EightChamber_web_03v1.jpg

Features
  • Isolated output eliminates the need for an external stimulus isolation unit
  • Perform completely independent stimulation protocols in each tissue bath or vessel chamber
  • Constant current stimulus in a low impedance solution such as physiological saline solution
  • Isolated monitor output allows the user to view the stimulus waveform using a separate oscilloscope
  • Stimulator parameters are set in the user-friendly CATSTIM software
  • Can be programmed to automatically deliver a sequence of stimulations using protocol files to encode the stimuli
  • No confusing knobs or switches to set

Pt EFS Electrodes for Dual Vessel ChamberSTIM-9.jpg

These high-quality platinum wires are designed to fit our CH-2 vessel chambers for users studying responsiveness to transmural nerve stimulation using electric field stimulation. The electrode wires are supplied with a BNC termination, facilitating connection to stimulus generators, including our C-STIM-150I series constant current stimulators.

STIM-3.jpg

STIM-2.jpg

Pt EFS Electrodes for Single Vessel Chamber
These high-quality platinum wires are designed to fit our CH-1 vessel chambers for users studying responsiveness to transmural nerve stimulation using electric field stimulation. The electrode wires are supplied with a BNC termination, facilitating connection to stimulus generators, including our C-STIM-150I series constant current stimulators.

STIM-MYO_PlatinumEFSelectrodes_web_6649v1.jpg

STIM-MYO_PlatinumEFSelectrodes_web_6652v2.jpg

Pt EFS Electrodes for Wire Myograph and Linear Chamber
These high-quality platinum wires are designed to fit our CH-1-LIN Linear Vessel chamber and MYO-CH wire myograph chamber for users studying responsiveness to transmural nerve stimulation using electric field stimulation. The electrode wires are supplied with a BNC termination, facilitating connection to stimulus generators, including our C-STIM-150I series constant current stimulators.