SuperArgus PET/CT

Advanced Preclinical PET/CT System with High Sensitivity and Resolution

Imaging Gallery

Applications

Webinars

Features

System Overview

The SuperArgus PET/CT is a high-performance imaging system for preclinical research. It can be configured as a combined PET/CT or PET or CT only system, and features state-of-the-art phoswich PET detectors with true depth-of-interaction (tDOI) for resolution uniformity and high sensitivity.

Available in three bore sizes, the system offers real-time imaging up to 2.5msec frame rate and advanced capabilities like sensorless cardiac gating and conscious/awake imaging.

 

The dual-modality configuration delivers fast scan times with superior image resolution, improved localization, and quantifiable data. In addition, the SuperArgus PET/CT has been designed with a user-friendly operator interface and easy animal positioning.

Features & Benefits

Superior Resolution (≤1.0mm)

  • Ability to image small anatomical structures

  • Locate small metastatic tumors

Multiplexed Imaging (mPET)
  • Simultaneously acquire images from two different tracers, upon post-processing the data can be separated for each tracer.
  • Study interactions of different biomarkers of interest in the same model
Conscious/Awake Imaging
  • With the help of Fiducial markers, generate 3D & 4D data, and monitor changes dynamically without the effects of anesthesia 

Phoswich PET Detector Technology

  • Resolution Uniformity across the entire Field of View due to true Depth of Interaction (tDOI) 
  • Great for multi-animal imaging 

Real-time Imaging up to 2.5 millisecond frame rate

  • Real-time imaging allows users to confirm the success of injections
  • Dynamic studies with high frame rate
  • First-pass imaging
  • Sensorless cardiac gating
  • PET Guided Biopsies
  • Image Guided Radiotherapy

11% Sensitivity at 100 to 700 keV

  • Use smaller amounts of tracers to acquire high resolutions imaging 
Sensorless Cardiac Gating
  • Fully automated heartbeat detection
  • No wires or special positioning within the FOV
  • Capable with multi-animal setup
  • Quantifiable Cardiac Imaging
Multi-animal Imaging
  • High-throughput imaging without compromising on resolution and sensitivit

Models & Specifications

Systems can be configured as standalone PET systems or incorporated with computed tomography (CT) that delivers a low dosage of radiation with a resolution as low as 15µm and rapid scans as low as 8.5 seconds.

Model 2r 4r 6r 2R 4R 6R 2P 4P 6P

Fixed axial field of view (mm) 

50
10
150
50
100
150
50
100
150

Dynamic axial field of view  

220
220
220
350
350
350
650
650
650

Transaxial field of view (mm) 

80
80
80
120
120
120
210
210
210

Bore Size (mm)

90
90
90
160
160
160
260
260
260

Number of PET Rings 

2
4
6
2
4
6
2
4
6

Number of Detectors  

28
56
84
48
96
144
64
128
192

Number of DOI Crystals

9464
18928
28392
16224
32448
48672
21632
43264
64896

Accessories & Add-ons

  • Integrated temperature control and physiological monitoring 

  • Cardiac and respiratory gating 

  • Anesthesia control 

  • Animal transfer bed  

Applications

Past Webinars - PET/CT